Semi-DRYCUT SYSTEM IV replaces traditional coolant pump. Namely, just take out coolant pump and connect Semi-DRYCUT SYSTEM IV to coolant intake port of the machine. Micro-mist runs through coolant piping or through-spindle, and strongly blows out from the machine's nozzle or oil hole drill.Aim:
Good quality micro-mist must be strongly blown out from nozzle or oil hole drill. It must run through even high RPM rotating spindle without sticking to the inside wall of spindle, and can be blown out even from small oil hole drill. Besides, it must be trouble-free. To fulfill this aim, we developed special air-circut in the main body.
1) Very fine and even micro-mist.
2) Strong blowing.
3) Automatic adjustment of oil consumption in relation to nozzle size.
4) Trouble free. - Maintenance feee.
Technical Features:
1) Micro-mist is blown out even from φ1.0mm nozzle. The pressure of micro-mist is nearly same as Supply Air Pressure. When air is supplied at 0.5 MPa, the pressure of micro-mist at the blow-out port is nearly 0.5 MPa. By this strong pressure, micro-mist runs through coolant piping of the machine or high RPM rotating spindle, and is blown out even through φ1.0mm nozzle. (Test by our Testing Apparatus.)
2) Automatic Adjustment of Oil Volume. When nozzle size varies, oil volume is automatically adjusted. When nozzle size is larger, air flow is larger and oil volume is automatically larger. Likewise, when nozzle size is smaller, oil volume is smaller. Nearly same thick mist is constantly blown out irrespective of nozzle size variation. When oil is fed by pump, piston movement must be changed by M-signal, and programming and its change are quite troublesome.
3) Maintenance-free. In our SYSTEM, micro-mist is generated by special air pressure control circuits. Piston pump is not used, and there is no wearing parts. Thus, it is trouble-free and maintenance -free.
Main Specifications:
| Dimension & Weight | 165(W)x145(D)x269(H)mm approx. 6.0 kgs |
| Oil Reservoir Capacity | approx. 1,000 cc |
| Supply Air Pressure | 0.4 〜0.6 MPa |
| Oil Volume Initial Setting | By Oil Volume Control Knob Then, oil volume is automatically adjusted whenever nozzle size varies. Troublesome M-signal setting is not needed at all. |